You are currently not taking any of our courses.
Educate both your staff and your customers with our different courses!
ACUVUE® OASYS Contact Lenses for ASTIGMATISM are part of the ACUVUE® OASYS family that is the #1 selling contact lens brand in the world.* Leveraging EYELID STABILISED design, ACUVUE® OASYS Contact Lenses for ASTIGMATISM provide clear, stable vision. They use four stabilisation zones with the lids to help keep the lens in place, even with eye or head movements.1
8.6 mm base curve/14.5 mm diameter
Low minus power range:
Plano to -6.00D (0.25D steps)
CYL: -0.75, -1.25, -1.75
AXIS: 10° to 180° (10° increments)
CYL: -2.25, -2.75
AXIS: 10°, 20°, 70°, 80°, 90°, 100°, 110°, 160°, 170°, 180°
High minus power range:
-6.50D to -9.00D (0.50D steps)
CYL: -0.75, -1.25
AXIS: 10° to 180° (10° increments)
CYL: -1.75, -2.25, -2.75
AXIS: 10°, 20°, 160°, 170°, 180°
Plus power range:
+0.25D to +6.00D (0.25D steps)
CYL: -0.75, -1.25, -1.75
AXIS: 10°, 20°, 70°, 80°, 90°, 100°, 110°, 160°, 170°, 180°
Daily wear – replace every two weeks
Extended wear up to six nights/seven days – replace every seven days
Lens material | senofilcon A |
Technology | HYDRACLEAR® PLUS & EYELID STABILISED® Design |
Dk/t (edge-corrected)3◊ | 129 x 10-9 |
Water content | 38% |
UV-blocker3† | Class 1 |
Center thickness at-3.00D (mm) | 0.080 |
Visibility tint | Yes |
Inside-out Mark | No |
Package size | 6 lenses |
*All ACUVUE® Brand Contact Lenses have Class 1 or Class 2 UV-blocking to help provide protection against transmission of harmful UV radiation to the cornea and into the eye. UV-absorbing contact lenses are NOT substitutes for protective UV-absorbing eyewear such as UV-absorbing goggles or sunglasses because they do not completely cover the eye and surrounding area.
1. Sulley A, Madec-Hily A, Packe R. Large scale survey of senofilcon A contact lens wearers. Optom Vis Sci 2012 E-abstract 125443.
2. Oxygen transmissibility at centre of a -3.00D lens using boundary-corrected, edge-corrected Dk values. Units: (cm/sec)(ml O2/ml x mm Hg) at 35° C. Dk determined via polarographic method.
3. Oxygen flux - % available to central cornea (open eye) and compared to 100% with no lens. .
4. Corneal oxygen consumption calculated using Brennan method which represents an index of corneal oxygen metabolism during open eye and thus cellular energy production. Brennan NA. OVS. 2005 Jun; 82(6):467-72. Brennan N, Morgan P. CLAE 2009, 32 (5): 210-254.
EYELID STABILISED is based on a four-zone stability system that utilises positive eyelid interaction by harnessing the power of the eye blink.1Legal
Packing solution contains boric acid and disodium tetraborate (sodium borate) to control the pH of the solution.
*Source Euromonitor International Limited; Eyewear2023 edition; value sales at rsp, all retail channels, 2021 data.
‡Clinicaltrials.gov is a website maintained by the NIH. Since February 2007, 25 clinical studies evaluated subjective comfort as a primary or secondary endpoint for ACUVUE® OASYS Brand 2-weekly family contact lenses. Review conducted as of April 29, 2022.
†All ACUVUE® contact lenses have Class 1 or Class 2 UV-blocking to help provide protection against transmission of harmful UV radiation to the cornea and into the eye. UV-absorbing contact lenses are NOT substitutes for protective UV-absorbing eyewear such as UV-absorbing goggles or sunglasses because they do not completely cover the eye and surrounding area. UV transmission measured with -1.00 lens.
^ClinicalTrials.gov is a website maintained by the NIH. The 25 clinical studies evaluated subjective comfort as a primary or secondary endpoint for ACUVUE® OASYS Brand 2-weekly family contact lenses. Review conducted as of April 29, 2022.
$ClinicalTrials.gov is a website maintained by the NIH. The 25 clinical studies evaluated subjective comfort as a primary or secondary endpoint for ACUVUE® OASYS Brand family and ACUVUE® OASYS with Transitions contact lenses. Review conducted as of April 29, 2022.
◊Oxygen is only one of several factors related tomaintaining overall eye health when wearing contact lenses.
1.JJV Data on File 2021. ACUVUE Brand ContactLenses for ASTIGMATISM - Overall FittingSuccess, Orientation Position, Rotational Stability,and Vision Performance.
2.JJV Data on File 2022. Proportion AstigmatsAccommodated with ACUVUE® Brand ContactLenses for ASTIGMATISM.
3.JJV Data on File 2019. Material Properties forReusable Toric Contact Lenses, IncludingACUVUE OASYS Brand Contact Lenses forASTIGMATISM and ACUVUE VITA BrandContact Lenses for ASTIGMATISM.
4.JJV Data on File 2018. Similarities between Mucin and Poly(N-Vinyl Pyrrolidone) (PVP).
5.JJV Data on File 2016. 30-day dispensingevaluation, monthly replacement DW study, n =533 soft silicone hydrogel contact lens wearers inthe U.S.
6.JJV Data on File 2017. 30-day dispensingevaluation, monthly replacement DW study, n =226 soft toric CL wearers in the U.S.
7.Berntsen DA, Hickson-Curran SB, Jones LW, etal. Subjective Comfort and Physiology withModern Contact Lens Care Products. Optom VisSci. 2016,93(8):809-819.
8.JJV Data on File 2017. Multi-center 1-monthdispensing daily wear study with senofilcon Ctoric contact lenses with RevitaLens OcuTecMPDS, worn for 30 days, n=130 habitual soft toriccontact lens wearers in US.
9.JJV Data on File 2016. Multi-center 1-monthdispensing daily wear study with comfilcon A toric using RevitaLens OcuTec MPDS, n=95 habitualsoft toric contact lens wearers in the US.
10.JJV Data on File 2017. RevitaLens OcuTec MPDScompatibility and clinical performance withACUVUE Brand Contact Lenses (2 week dailywear study with senofilcon A, etafilcon A &galyfilcon A, n=203 habitual soft contact lenswearers; 1-month daily wear study with senofilconC toric contact lenses, N=130 habitual soft toriccontact lens wearers, in-vitro laboratoryevaluations with ACUVUE Brand reusable contactlens materials).
11.JJV Data on File 2012-2015. Laboratoryevaluations with RevitaLens OcuTec MPDS andreusable contact lens materials (senofilcon A,senofilcon C, etafilcon A & galyfilcon A).
12.JJV Data on File 2018. ACUVUE RevitaLensMultipurpose